Wednesday, 7 November 2012

Dynamicanalysis of electrostatically exited micro cantilever beam


A, J S N B Vamsee (2011) Dynamicanalysis of electrostatically exited micro cantilever beam. MTech thesis.

[img]PDF
2018Kb

Abstract

Microcantilever beams find applications in modern micro and nano devices, such as, microswitches, microvalves and atomic force microscopes (AFM). These are generally
fabricated from single crystal silicon. Dynamics and pull-in analysis of these cantilever resonators (Beams) is of vital importance before their fabrication. Microbeams are often actuated by several actuation techniques such as piezoelectric, electromagnetic, thermal and electrostatic
excitations. In electrostatic actuation a controlled dc voltage is applied together with a harmonic or suddenly applied ac component. The electrostatic force is in fact a non-linear function of displacement of the beam. In such beams when electrostatic force exceeds the elastic restoring
force in the beam contact between the beam and supporting substrate occurs. This situation is referred to as pull-in instability which defines the life of a resonator. The study of pull-in is very important to design process of microsystems, such as, microgyroscopes to analyze the frequency response, the dynamic range and sensitivity.
In this line, present work attempts to predict the static and dynamic characteristics of a cantilever microbeam resonator. A single-DOF model incorporating squeeze-film damping forces is first considered. Dynamic pull-in voltages are obtained from time-domain analysis and
phase trajectories, for values of ac voltage amplitudes. Parametric studies are carried-out to find the effect of ac voltage amplitudes and air film pressure on the intermediate stability of system. For this bifurcation analysis and Poincare maps are employed. The harmonic voltage frequency effects are also illustrated in the form of frequency-response curves. As stiffness of test structure
reduces due to applied voltage, the spring –softening behavior is observed in frequency-response curves. Two benchmark cantilever beam geometries available in terature are considered to illustrate the approach.
Item Type:Thesis (MTech)
Uncontrolled Keywords:Mems,Dynamic analysis,Micro Cantilever Beam
Subjects:Engineering and Technology > Mechanical Engineering > Machine Design
Divisions:Engineering and Technology > Department of Mechanical Engineering
ID Code:2932
Deposited By:Vamsee Gowtham A. J. S. N. B
Deposited On:13 Jun 2011 14:57
Last Modified:13 Jun 2011 14:57
Supervisor(s):Srinivas, J

0 comments: