Introduction
This tutorial was created using ANSYS 7.0 The purpose of this tutorial is to outline the steps required to do a simple nonlinear analysis of the beam shown below.
There are several causes for nonlinear behaviour such as Changing Status (ex. contact elements), Material Nonlinearities and Geometric Nonlinearities (change in response due to large deformations). This tutorial will deal specifically with Geometric Nonlinearities .
To solve this problem, the load will added incrementally. After each increment, the stiffness matrix will be adjusted before increasing the load.
The solution will be compared to the equivalent solution using a linear response.
Preprocessing: Defining the Problem
- Give example a Title
Utility Menu > File > Change Title ... - Create Keypoints
Preprocessor > Modeling > Create > Keypoints > In Active CSWe are going to define 2 keypoints (the beam vertices) for this structure to create a beam with a length of 5 inches: Keypoint Coordinates (x,y) 1 (0,0) 2 (5,0) - Define Lines
Preprocessor > Modeling > Create > Lines > Lines > Straight LineCreate a line between Keypoint 1 and Keypoint 2. - Define Element Types
- Define Real Constants
- Cross-sectional area AREA: 0.03125
- Area Moment of Inertia IZZ: 4.069e-5
- Total beam height HEIGHT: 0.125
- Define Element Material Properties
Preprocessor > Material Props > Material Models > Structural > Linear > Elastic > IsotropicIn the window that appears, enter the following geometric properties for steel: - Young's modulus EX: 30e6
- Poisson's Ratio PRXY: 0.3
- Define Mesh Size
Preprocessor > Meshing > Size Cntrls > ManualSize > Lines > All Lines...For this example we will specify an element edge length of 0.1 " (50 element divisions along the line). - Mesh the frame
Preprocessor > Meshing > Mesh > Lines > click 'Pick All'
LMESH,ALL
Solution: Assigning Loads and Solving
- Define Analysis Type
- Set Solution Controls
- Select Solution > Analysis Type > Sol'n Control...The following image will appear:
Ensure the following selections are made (as shown above)- Ensure Large Static Displacements are permitted (this will include the effects of large deflection in the results)
- Ensure Automatic time stepping is on. Automatic time stepping allows ANSYS to determine appropriate sizes to break the load steps into. Decreasing the step size usually ensures better accuracy, however, this takes time. The Automatic Time Step feature will determine an appropriate balance. This feature also activates the ANSYS bisection feature which will allow recovery if convergence fails.
- Enter 5 as the number of substeps. This will set the initial substep to 1/5 th of the total load.The following example explains this: Assume that the applied load is 100 lb*in. If the Automatic Time Stepping was off, there would be 5 load steps (each increasing by 1/5 th of the total load):
- 20 lb*in
- 40 lb*in
- 60 lb*in
- 80 lb*in
- 100 lb*in
Now, with the Automatic Time Stepping is on, the first step size will still be 20 lb*in. However, the remaining substeps will be determined based on the response of the material due to the previous load increment. - Enter a maximum number of substeps of 1000. This stops the program if the solution does not converge after 1000 steps.
- Enter a minimum number of substeps of 1.
- Ensure all solution items are writen to a results file.
There are several options which have not been changed from their default values. For more information about these commands, type help followed by the command into the command line.Function Command Comments Load Step KBC Loads are either linearly interpolated (ramped) from the one substep to another (ie - the load will increase from 10 lbs to 20 lbs in a linear fashion) or they are step functions (ie. the load steps directly from 10 lbs to 20 lbs). By default, the load is ramped. You may wish to use the stepped loading for rate-dependent behaviour or transient load steps. Output OUTRES This command controls the solution data written to the database. By default, all of the solution items are written at the end of each load step. You may select only a specific iten (ie Nodal DOF solution) to decrease processing time. Stress Stiffness SSTIF This command activates stress stiffness effects in nonlinear analyses. When large static deformations are permitted (as they are in this case), stress stiffening is automatically included. For some special nonlinear cases, this can cause divergence because some elements do not provide a complete consistent tangent. Newton Raphson NROPT By default, the program will automatically choose the Newton-Raphson options. Options include the full Newton-Raphson, the modified Newton-Raphson, the previously computed matrix, and the full Newton-Raphson with unsymmetric matrices of elements. Convergence Values CNVTOL By default, the program checks the out-of-balance load for any active DOF.
- Select Solution > Analysis Type > Sol'n Control...The following image will appear:
- Apply Constraints
- Apply Loads
- Solve the System
ANTYPE,0
SOLVE
This shows the convergence of the solution.
General Postprocessing: Viewing the Results
- View the deformed shape
General Postproc > Plot Results > Deformed Shape... > Def + undeformed
PLDISP,1 - View the deflection contour plot
General Postproc > Plot Results > Contour Plot > Nodal Solu... > DOF solution, UY
PLNSOL,U,Y,0,1 - List Horizontal Displacement
If this example is performed as a linear model there will be no nodal deflection in the horizontal direction due to the small deflections assumptions. However, this is not realistic for large deflections. Modeling the system non-linearly, these horizontal deflections are calculated by ANSYS.
General Postproc > List Results > Nodal Solution...> DOF solution, UX
Other results can be obtained as shown in previous linear static analyses.
Time History Postprocessing: Viewing the Results
As shown, you can obtain the results (such as deflection, stress and bending moment diagrams) the same way you did in previous examples using the General Postprocessor. However, you may wish to view time history results such as the deflection of the object and the step sizes of the load.
As you recall, the load was applied in steps. The step size was automatically determined in ANSYS
- Define Variables
- Select: TimeHist Postpro > Define Variables > Add... > Nodal DOF results
- Select Keypoint 2 (Node 2) when prompted
- Complete the following window as shown to define the translational displacement in the y direction.
Translational displacement of node 2 is now stored as variable 2 (variable 1 being time)
- Graph Results over time
- Select TimeHist Postpro > Graph Variables...
- Enter 2 (UY) as the 1st variable to graph (shown below)
0 comments: